  1. HW 8000 Trolley Withstand High Voltage Pulse Generator

HW 8000 Trolley Withstand High Voltage Pulse Generator

  1. MOQ: 1 unit
  2. Price:
  3. Get Latest Price
Model HW 8000
Working mode DC/Single/Cycle
Discharge 0-8450J
Output voltage 0-35kV
Display Analog meter or from ARC TDR
Connection to ARC TDR

View Detail Information

Inquiry by Email Get Latest Price
  1. Product Details

Product Specification

Model Number HW 8000 Discharge 0-8450J
Working mode DC/Single/Cycle Output voltage 0-35kV
Display Analog meter or from ARC TDR Place of Origin China

HW 8000

 This high voltage surge generator HW 8000 integrates DC high voltage source, energy storage capacitor, discharge ball device, automatic discharge device, and a cart-type high-end experimental instrument. The equipment completely solves the problems of convenience, portability, safety and reliability of traditional experimental devices.
This instrument uses high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, making the whole machine simple in structure. In order to retain people's original habit of using transformers and operating boxes to generate DC high voltage, this pulse generator adopts a humanized design operation mode and integrates a micro-reliable circuit design. It is safe, reliable and intuitive. Really achieve the effect of not being damaged by impact, and it also has the functions of automatic timing impact, manual impact and pressure resistance. It is currently the most user-friendly trolly-type DC impact high-voltage equipment.

Voltage Range: 0-35kV
High voltage divider: Voltage Accuracy 2.5 grade
Inside capacitor : 4uf
Surge time: Auto surge about 5s, also can control by hands.
Discharge energy: 8450J
Surge power: 8KVA
Impact time 7 second  automaticly
Weight:  about 159kg(4uF)
Power supply:  AC 220V + 10% 50Hz/±2Hz(other frequency can be customized)
Environment temperature:  -20 ~ +50 ºC
 

★ High-voltage pulse output is uniform and controllable;
★ With double 2.5-level pointer meter display of current and voltage, it is intuitive and clear, and the impact discharge process is clear at a glance;
★ High-voltage side voltage measurement, real-time and accurate;
★ With zero start protection function, safe and reliable;
★ Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device;
★ The discharge time can be selected in two modes: timing and manual;
★ With DC withstand voltage function;
★ Internally installed high-precision test cable fault sampling waveform module;
★ Humanized design trolley, easy to move.

Panel introduction
Ammeter: Show the current of low voltage side

Voltmeter: Show high voltage output

Zero: it means that the voltage adjustable knob is at the Zero . the Start key is effective if the Zero indicator is brighter only.

HV: High voltage output indicator light. Light is on means there has high voltage output. Otherwise, light is off there is no high voltage output.

Power: Power indicator is light and AC220V is normal after turn on the power switch.

Power switch: AC 220V 50Hz power input socket. Fuse holder and main power switch of device. 8A Fuse.

Single: The indicator will light when choose single discharge

Model select: Withstand Voltage, Single model and Cycle model. DC model is to start withstand voltage test to cable. Single model is discharge by hand controlling. Press the button of 7 and then adjust High voltage knob to control discharge time by hand. Cycle model is discharged automatically which means select this function to rise up voltage after start high voltage ,this device will be automatic trigger impulse discharge, time is about 5 seconds.

Stop: when the test is completed or abnormal, press the key to cut off the high voltage output, the start level will automatically fall, this will also automatic discharge remaining high voltage inside the device.

Start: At the zero state to pull up the start, the high-voltage is start, at the same time the High voltage light is on. At the non zero state, the start is invalid.

Signal: Use double Q cable connect the DC High Voltage Pulse Generator with cable fault locator, only at high voltage flashover is effective.

Voltage control: This knob is at the zero state, zero indicator is on, high voltage can start. After starting high voltage, can rise up the voltage by the voltage adjust knob.

Get in touch with us

  • Reach Us
  • Huilan Wuhan Technologies Co. Ltd
  • 68 Xiniuer St, Caidian District, Wuhan, Hubei, China

Leave a Message, we will reply within 24 hours!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

© Quality TDR Cable Fault Locator China Factory. All Rights Reserved (Terms of Use)

top
Contact Now
Glad to serve you!
In order to better meet your needs and facilitate communication, please choose the appropriate contact method to get in touch with us.
Thank You!
Good luck with your communication!

In Addition, the following verified suppliers are recommended to your requirement.

You can chat with them at any time for more quotations:

Continue Browsing